circuits and controls


Liquid Level Controller Type ELR10P

 
 
    Features
  • Control and regulation of liquid levels in tanks.
  • Completely solid state detection.
  • Conductive liquids, e.g., tap water, sea water, sweage, acid, alkali, chemicals, milk, coffee, etc.
  • Insulating liquids, e.g., insulating oils, kerosene,diesel, mobil, transformer oils, vegetable oils, etc.
  • Pump-up control.
  • PUMP DRY trip facility.
  • LED indication for Supply 'V' and Relay 'L' and 'PD'.

Liquid Level Controller
(ELR10P)

Introduction

Liquid Level Controller ELR10P is normally used to control level of liquids in overhead tanks.To sense the level of conducting liquids three stainless steel Electrode Type Level Sensors (ELR10S1) are used which are designated as HI (high level), LO          ( low level) and 'G' (ground). For insulating liquids and also some conducting liquids Float Type Level Sensors (ELR10S2) are used.

Mode of operation
 
 
  The relay is designed to work with the pump motor starter  
   It gets energised when the liquid level goes below the LO 
   level sensor and de-energised when it touches the HI level
   sensor. If the liquid is lifted from an underground or ground 
   level tank, the PD (Pump Dry) sensor can be fitted at a
   suitable low level in it, to de-energise the relay, when the 
   liquid level goes below it. In this case, care must be taken 
   to ensure the cause of such low level in the underground 
   tank and pump restarted only when there is suffiecient liquid
   in the tank. The relay contacts can be used to control the 
  starter coil of the pump motor.
                 Electrode Type                 Float Type

Technical Data
 
 
   Supply Voltage VAC      :   24V,110V,230V,415V
    Supply Frequency         :  50 - 60 Hz.
   Permissible Amb. Temp :  - 15 to + 55 deg.C.
   Permissible Voltage
   variation                      :  - 80 to 110% of V.
   Permissible frequency
   variation                      :  - 10 to + 10 %
  . Maxm.Power
   consumption                :   6.5 VA.
    Switching frequency      :   200 Cycles/hour.
 

 

  
   Insulation                    :   2500V AC for 1 min.
   Mechanical Life           :  10 million.
   Terminals                    :   Suitable for 2x2.5 sq.mm.
                                                  cable. 
  AC Contact Rating       : Continuous capacity 6A
  ( at 250 VAC 50 Hz )        Rated making capacity11A 
                                        Rated breaking capacity
                                        5A    (Resistive)
                                        1.3A  (Inductive 0.5 pf.)
  Mounting                    :  Projection (ELR10P)
   Weight                       : 460 gms.
   
 

 For Further details please E-mail to us

circon@.vsnl.com